BLX-8 PLUS Portable Handheld Portable Dental X Ray Unit
Tube voltage |
tube current |
exposal time |
Focus point |
60kv |
0.1MA |
0.5-90 S |
0.3MM |
TECHNICAL SPECIFICATIONS:
Tube Voltage |
60kV |
Tube Current |
1mA |
Time Exposure |
1~~9s |
High pressure generator |
30kHz DC |
Rated Power |
60w |
Focal Spot To Skin Distance |
>20CM |
Focus Spot Size |
0.3mm(TOSHIBA) |
Charger Input Voltage |
AC110V~220V |
Supply Frequency |
50Hz±1% |
Radiation Leakage |
<20ugy/h |
Battery |
24V DC 8000MA |
Weight |
2KG |
Dimensions |
25 cm×11..5 cm×17cm (L×W×H |
Operation of the Main Unit
- Upon receiving,open the box and check the product for possible damage during shipping.
- Make sure the fittings on the encasement list are packaged within the box.
- Install the blue ray tube to the foreside of the ball head,then tighten it.
- Turn on the Power;the pilot lamp will be light up.During this time,the digital tube will show the fore setting time. Now the equipment is in standby mode.
- Setting the time (Skip to next step if unneeded) Use the "SET","+",and" -" buttons to reset the time as follows: press SET,the pilot lamp above is illuminated, the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
- Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)
- Keep the ball head plumb to the tooth projection position; Have the ball head,tooth, and tooth film steadily mutually plumb.
- After positioning,use the ON/OFF on the main Unit, to take pictures. (Notice: gently press 0.5 sec to turn it on)
- After exposure to the tube,press the start button again in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray,so the dental films can be used again).
- Repeat step 6 to reset the picturing time.To repeat the picturing process,please repeat steps 7 to 9.
- Turn the power off when the work is finished,press POWER, making sure the pilot lamp is off.Don't keep the machine long in standby mode.
Reference of the Angles
' |
|
|
Tooth |
Upper |
Lower |
1-2 |
42 |
-15 |
3 |
45 |
-18 |
4-5 |
30 |
-10 |
6-8 |
28 |
-5 |
Reference of the time of exposure
Tooth |
Adult |
Child |
Central & Lateral |
2.5-3.25 |
2-2.7 |
Cuspid & 1st Bicuspid |
3.2-4 |
2.7-3.5 |
Upper 5,6 |
3.5-4 |
3-3.5 |
Upper 7,8 |
7.5-8 |
7-7.5 |
Lower 5,6 |
4-4.5 |
3.5-4 |
Lower 7,8 |
4-4.5 |
3.5-4 |